Lenze L-force HighLine C 8400 Series Reference Manual page 940

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Parameter reference
Parameter list | C01215
C01215
Parameter | Name:
C01215 | MCK: Following error
Limits for following error monitoring system
Setting range
(min. value | unit | max. value)
0.0000
Subcodes
C01215/1
C01215/2
Read access
C01216
Parameter | Name:
C01216 | MCK: Positioning setting
From version 04.00.00
Setting range
(min. hex value | max. hex value)
0x00
Value is bit-coded: (
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Read access
940
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
units
214748.0000
Lenze setting
0.0000 units
0.0000 units
Write access
CINH
PLC STOP
= bit set)
PosAbort at PosInit
PosExecute active at PosInit
Reserved
Reserved
ProfilStart at PosInit
Reserved
Reserved
Reserved
Write access
CINH
PLC STOP
L
Info
MCK: Following error limit 1
• First limit of the maximum following error for
monitoring and response activation.
MCK: Following error limit 2
• Second limit of the maximum following error for
monitoring and response activation.
No transfer
COM
MOT
Scaling factor: 10000
Lenze setting
0xFF 0x01 (decimal: 1)
No transfer
COM
MOT
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: INTEGER_32
Index: 23360
= 5B40
d
Following error monitoring system
Data type: UNSIGNED_8
Index: 23359
= 5B3F
d
Positioning
h
h

Hide quick links: