8400 HighLine C | Reference manual
Parameter reference
Parameter list | C00968
C00968
Parameter | Name:
C00968 | VFC: Voltage interpol. point n
From version 04.00.00
Selection of the interpolation points (voltage values) for the V/f characteristic control (VFCplus) with user-definable
V/f characteristic
Setting range
(min. value | unit | max. value)
0.00
Subcodes
C00968/1
C00968/2
C00968/3
C00968/4
C00968/5
C00968/6
C00968/7
C00968/8
C00968/9
C00968/10
C00968/11
Read access
C00971
Parameter | Name:
C00971 | VFC: Limitation V/f +encoder
Limitation of the output frequency of the slip regulator and limitation of the injected stator frequency for the V/f
control (VFCplus+encoder)
Setting range
(min. value | unit | max. value)
0.00
Subcodes
C00971/1
C00971/2
Read access
C00972
Parameter | Name:
C00972 | VFC: Vp V/f +encoder
Proportional gain of the slip regulator for V/f control (VFCplus+encoder)
• The gain must be selected depending on the drive system and the sensor resolution (range: 0.005 ... 5).
• A high gain requires a high number of increments.
Setting range
(min. value | unit | max. value)
0.000
Read access
906
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
(C00006
= "10")
V
Lenze setting
400.00 V
320.00 V
240.00 V
160.00 V
80.00 V
0.00 V
80.00 V
160.00 V
240.00 V
320.00 V
400.00 V
Write access
CINH
PLC STOP
Hz
Lenze setting
10.00 Hz
100.00 Hz
Write access
CINH
PLC STOP
Hz/Hz
Write access
CINH
PLC STOP
L
600.00
Info
VFC: Voltage interpol. point 1
VFC: Voltage interpol. point 2
VFC: Voltage interpol. point 3
VFC: Voltage interpol. point 4
VFC: Voltage interpol. point 5
VFC: Voltage interpol. point 6
VFC: Voltage interpol. point 7
VFC: Voltage interpol. point 8
VFC: Voltage interpol. point 9
VFC: Voltage interpol. point 10
VFC: Voltage interpol. point 11
No transfer
COM
MOT
Scaling factor: 100
100.00
Info
Maximum output / correcting variable of the slip
regulator
• The slip regulator output is limited to the value set
here in motor/generator mode.
• It is recommended to select 1 to 3 times the slip
frequency of the motor as limit value.
Maximum frequency deviation between the rotational
frequency (speed) measured mechanically by the
encoder and the injected stator frequency.
• A limitation may e.g. avoid overcurrent interruption
when traversing to a fixed limit stop.
No transfer
COM
MOT
Scaling factor: 100
Lenze setting
64.000 0.100 Hz/Hz
No transfer
COM
MOT
Scaling factor: 1000
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_16
Index: 23607
= 5C37
d
h
Data type: UNSIGNED_16
Index: 23604
= 5C34
d
h
Data type: UNSIGNED_16
Index: 23603
= 5C33
d
h