Lenze L-force HighLine C 8400 Series Reference Manual page 965

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

C02589
Parameter | Name:
C02589 | Holding brake: Time system
Operating times of the holding brake
• The electromechanical delay times of the holding brake are specified in the data sheets or on the holding brake
nameplate.
Setting range
(min. value | unit | max. value)
0
Subcodes
C02589/1
C02589/2
C02589/3
C02589/4
Read access
C02593
Parameter | Name:
C02593 | Holding brake: Activation time
Time parameter for the delay of trigger signals of the holding brake control
Setting range
(min. value | unit | max. value)
0.000
Subcodes
C02593/1
C02593/2
C02593/3
C02593/4
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
ms
Lenze setting
100 ms
100 ms
100 ms
0 ms
Write access
CINH
PLC STOP
s
Lenze setting
0.000 s
0.000 s
0.000 s
0.000 s
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
60000
Info
Holding brake: Application time
• Time in which the holding brake is completely applied
from the beginning of control and in which the
controller is inhibited.
Holding brake: Release time
• Time in which the holding brake is completely
released from the beginning of control.
Holding brake: Waiting time status
• Time after which all transient reactions are
completed and the switching status of the holding
brake is stable. Beginning of monitoring the feedback
signal for the switching status of the holding brake.
Holding brake: Ramp time FF ctrl
From version 06.00.00
No transfer
COM
MOT
Scaling factor: 1
3600.000
Info
Holding brake: Actual value monitoring
• Time in which the actual value is supposed to reach
the threshold for closing the brake if the setpoint has
already reached the threshold.
• Time > 0 s: If the actual speed value has not reached
the threshold within the time for brake application,
the holding brake is applied by control.
• Time = 0 s: The brake is only applied by control when
the actual speed has reached the application
threshold.
Holding brake: Application delay
• Time by which the control process for holding brake
application is delayed. The time expires when the
speed setpoint has reached the switching threshold
for application.
• With positioning processes, a continuous application
and release of the holding brake can thus be
suppressed for the set time.
Holding brake: Reserved
Holding brake: Reserved
No transfer
COM
MOT
Scaling factor: 1000
Parameter reference
Parameter list | C02589
Data type: UNSIGNED_16
Index: 21986
= 55E2
d
h
Holding brake control
Data type: UNSIGNED_32
Index: 21982
= 55DE
d
h
Holding brake control
965