8400 HighLine C | Reference manual
I/O terminals

Digital output terminals

6.2
Digital output terminals
The drive controller has
 three parameterisable output terminals (DO1 ... DO3) for outputting digital signals
 a relay output (terminal strip X101),
 a (high-current) output for controlling a brake (terminal strip X107).
Note!
Initialisation behaviour:
• After mains switching up to the start of the application, the digital outputs
remain set to FALSE.
Exception handling:
• In case of a critical exception in the application (e.g. reset), the digital outputs
are set to FALSE considering the terminal polarity parameterised in C00118.
Switching cycle diagnostics of the relay:
• A reference for evaluating the wear limit can be obtained via the number of
switching cycles of the relay displayed in C00177/2.
Parameterisation dialog in the »Engineer«:
330
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
L
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011