Commissioning
Commissioning of the "Table positioning" technology application
3.7.4.3

Set homing

Detailed information on the "Homing" operating mode is provided in chapter
"Basic drive functions" in subchapter "Homing".
1. Click the
change to the Overview  Signal flow  Homing dialog level:
2. Select the homing mode and hence the type of homing via the
or directly in the
– A graphic display of all possible homing modes can be seen via the Homing mode
button.
– In this system constellation without touch probe, the preset ">_Lp" mode can be
used: movement in positive direction, positive edge of the limit switch sets
reference.
3. Set the position to be used for loading the set position and the actual position after
homing has finished in the
76
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
button (in the "MotionControlKernel" block) in the signal flow to
Homing mode list field (C01221).
Homing home position input field (C01227/2).
L
( 494)
Homing mode button
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011