5.11

Encoder/feedback system

For the motor controls with speed monitoring the feedback signal can be supplied via an
HTL encoder at the digital input terminals (DI1/DI2 or DI6/DI7).
Danger!
• In order to prevent interference injections when using an encoder, only use
shielded motor and encoder cables.
• If an HTL encoder is used at the digital input terminals:
Observe the maximum input frequencies of the digital inputs!
– DI1/DI2: max. 100 kHz
– DI6/DI7: max. 10 kHz
Note!
In the Lenze setting (e.g. when the device is delivered), the open-circuit
monitoring of the encoder is activated.
( 300)
Wiring diagram, assignment and electrical data of the digital input terminals
can be found in the 8400 hardware manual in the chapter "Technical data".
• The hardware manual has been stored in electronic form on the data carrier
supplied with the 8400 drive controller.
[5-30] Signal flow - encoder interface
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Speed encoder
selection
C00420/1
Encoder number of incr.
C00495
C00425/1
Encoder sampling time
100 kHz
FreqIn12
Position encoder
selection
C00490
C00420/2
Encoder number of incr.
C00425/2
Encoder sampling time
10 kHz
FreqIn67
L
8400 HighLine C | Reference manual
Encoder open-circuit monitoring
Filter time
C00497/1
FreqIn12
C00497/2
FreqIn67
0
1
2
C00496
Encoder evaluation procedure
0
1
2
Motor control (MCTRL)
Encoder/feedback system
Speed controller/
slip regulator
C00051
Actual speed value
Position controller
C00254
Kp position controller
269