Lenze L-force HighLine C 8400 Series Reference Manual page 910

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Parameter reference
Parameter list | C00991
C00991
Parameter | Name:
C00991 | Flying restart fct.: Process
Selection of the starting value and the speed search range for the flying restart function
Selection list
(Lenze setting printed in bold)
Read access
C00992
Parameter | Name:
C00992 | Flying restart fct.: Start frequency
Manual selection of the starting value for the flying restart function
• Only active if
Setting range
(min. value | unit | max. value)
-200
Read access
C00993
Parameter | Name:
C00993 | Flying restart fct: Int. time
Time constant of the angular difference controller of the flying restart function
• The time constant is to amount between 60 ... 300 ms.
Setting range
(min. value | unit | max. value)
0.0
Read access
C00994
Parameter | Name:
C00994 | Flying restart fct.: Current
Current to be injected during the flying restart process
• 100 % ≡ rated motor current (C00088).
• The flying restart current should amount to 10 ... 25 % of the rated motor current.
Setting range
(min. value | unit | max. value)
0.00
Read access
910
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 0...+n | Start: +10 Hz
1 -n...0 | Start: -10 Hz
2 -n...+n | Start: +10 Hz
3 -n...+n | Start: -10 Hz
4 -n...+n | Start: Cx992
Write access
CINH
PLC STOP
C00991
= 4
Hz
Write access
CINH
PLC STOP
ms
Write access
CINH
PLC STOP
%
Write access
CINH
PLC STOP
L
Info
Search positive speed range (0 ... +n) with a start
frequency of +10 Hz
Search negative speed range (-n ... 0) with a start
frequency of -10 Hz
Search negative and positive speed range (-n ... n) with a
start frequency of +10 Hz
Search negative and positive speed range (-n ... n) with a
start frequency of -10 Hz
Search the negative and positive speed range (-n ... n)
with the start frequency set in
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
200 10 Hz
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
6000.0 300.0 ms
No transfer
COM
MOT
Scaling factor: 10
Lenze setting
100.00 25.00 %
No transfer
COM
MOT
Scaling factor: 100
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_16
Index: 23584
= 5C20
d
h
Flying restart fct.
C00992
Data type: INTEGER_16
Index: 23583
= 5C1F
d
h
Flying restart fct.
Data type: UNSIGNED_16
Index: 23582
= 5C1E
d
h
Flying restart fct.
Data type: INTEGER_16
Index: 23581
= 5C1D
d
h
Flying restart fct.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents