 The maximum number of the nodes to be monitored depends on the device version:
– "BaseLine C": 1 Heartbeat Producer can be monitored.
– "StateLine": Up to 7 Heartbeat Producers can be monitored.
– "HighLine": Up to 15 Heartbeat Producers can be monitored.
 The node address(es) of the nodes to be monitored is/are set in
object I-1016, too.
Heartbeat event
The "Heartbeat event" is activated in the consumer if it does not receive any heartbeat
telegram from the producer within the heartbeat consumer time:
 The consumer changes from the "Operational" communication status to the "Pre-
Operational" communication status.
 The NMT master receives an emergency telegram containing emergency error code
0x8130.
 The response parameterised in
Note!
The heartbeat monitoring will not start until the first heartbeat telegram of a
monitored producer has been received successfully and the "Pre-Operational"
NMT status has been assumed.
The boot-up telegram counts as the first heartbeat telegram.
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
8400 HighLine C | Reference manual
C00592/5
is activated (Lenze setting: "No response").
L
System bus "CAN on board"
Monitoring
C00385/1...n