8400 HighLine C | Reference manual
Parameter reference
Parameter list | C00242
C00242
Parameter | Name:
C00242 | L_PCTRL_1: Operating mode
The
L_PCTRL_1
• Depending on the selection, the blue switches in the displayed signal flow are set accordingly in the Engineer on
the Application parameters tab for the
Selection list
(Lenze setting printed in bold)
Read access
C00243
Parameter | Name:
C00243 | L_PCTRL_1: Acceleration time influence
The
L_PCTRL_1
Setting range
(min. value | unit | max. value)
0.000
Read access
C00244
Parameter | Name:
C00244 | L_PCTRL_1: Deceleration time influence
The
L_PCTRL_1
Setting range
(min. value | unit | max. value)
0.000
Read access
C00245
Parameter | Name:
C00245 | L_PCTRL_1: PID output value
The
L_PCTRL_1
Display range
(min. value | unit | max. value)
-199.99
Read access
C00246
Parameter | Name:
C00246 | L_PCTRL_1: nAct_a internal
From version 04.00.00
FB L_PCTRL_1: Display of the internal actual value
Display range
(min. value | unit | max. value)
-199.99
Read access
760
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
FB: Selection of the operating mode
L_PCTRL_1
0 Off
1 nNSet + nNSet_PID
2 nSet_PID
3 nNSet_PID
4 nNSet + nSet_PID
5 nNSet || nSet_PID
Write access
CINH
PLC STOP
FB: Acceleration time for showing the PID output value
s
Write access
CINH
PLC STOP
FB: Deceleration time for masking out the PID output value
s
Write access
CINH
PLC STOP
FB: Display of the output value of the PID process controller
%
Write access
CINH
PLC STOP
%
Write access
CINH
PLC STOP
L
FB.
Info
The input setpoint nNSet_a is output without any
changes at the output nOut_a.
nNSet_a and nAct_a are used as PID input values. The
arriving nNSet_a is additively linked to the value output
by the PID element.
nSet_a and nAct_a are used as PID input values. The
input nNSet_a is not considered.
nNSet_a and nAct_a are used as PID input values. The
input nSet_a is not considered.
nSet_a and nAct_a are used as PID input values. The
arriving nNSet_a setpoint is additively linked to the value
output by the PID element.
nSet_a and nAct_a are used as PID input values. The
setpoint nNSet_a is output at the output nOut_a . The
PID output value is output at the output nPIDOut_a.
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
999.999 5.000 s
No transfer
COM
MOT
Scaling factor: 1000
Lenze setting
999.999 5.000 s
No transfer
COM
MOT
Scaling factor: 1000
199.99
No transfer
COM
MOT
Scaling factor: 100
199.99
No transfer
COM
MOT
Scaling factor: 100
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_8
Index: 24333
= 5F0D
d
h
Data type: UNSIGNED_32
Index: 24332
= 5F0C
d
h
Data type: UNSIGNED_32
Index: 24331
= 5F0B
d
h
Data type: INTEGER_16
Index: 24330
= 5F0A
d
h
Data type: INTEGER_16
Index: 24329
= 5F09
d
h