Lenze L-force HighLine C 8400 Series Reference Manual page 938

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Parameter reference
Parameter list | C01203
C01203
Parameter | Name:
C01203 | MCK: iG motor/position encoder
Gearbox factor - position encoder
• Entry of the gearbox factor as numerator/denominator ratio, with numerator = motor speed and denominator
= position encoder speed.
Setting range
(min. value | unit | max. value)
1
Subcodes
C01203/1
C01203/2
Read access
C01204
Parameter | Name:
C01204 | MCK: Feed constant
The feed constant corresponds to the machine movement for one revolution of the gearbox output shaft.
• The value is entered in application units referred to one revolution.
Setting range
(min. value | unit | max. value)
0.0001
Read access
C01205
Parameter | Name:
C01205 | MCK: Position resolution
Display of the number of increments corresponding to one unit.
• 1 motor revolution ≡ 65536 increments
Display range
(min. value | unit | max. value)
0.0000
Read access
C01206
Parameter | Name:
C01206 | MCK: Mounting direction
Inversion for mirrored motor and encoder mounting
Selection list
Subcodes
C01206/1
C01206/2
Read access
938
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Lenze setting
1
1
Write access
CINH
PLC STOP
units/rev.
214748.3647 360.0000 units/rev.
Write access
CINH
PLC STOP
Incr./unit
214748.3647
Write access
CINH
PLC STOP
0 not inverted
1 inverted
Lenze setting
0: Not inverted
0: Not inverted
Write access
CINH
PLC STOP
L
65535
Info
MCK: iG: Numerator (motor speed)
MCK: iG: Denominator (encoder speed)
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
No transfer
COM
MOT
Scaling factor: 10000
No transfer
COM
MOT
Scaling factor: 10000
Info
Motor mounting direction
• Setting for motor mounting turned by 180°.
Position encoder mounting direction
• Setting for position encoder system mounting turned
by 180°.
No transfer
COM
MOT
Scaling factor: 1
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_16
Index: 23372
= 5B4C
d
h
Machine parameter
Data type: INTEGER_32
Index: 23371
= 5B4B
d
h
Machine parameter
Data type: INTEGER_32
Index: 23370
= 5B4A
d
h
Machine parameter
Data type: UNSIGNED_8
Index: 23369
= 5B49
d
h
Machine parameter

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents