Lenze L-force HighLine C 8400 Series Reference Manual page 963

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

C02580
Parameter | Name:
C02580 | Holding brake: Operating mode
Selection of the operating mode for holding brake control
Selection list
(Lenze setting printed in bold)
Read access
C02581
Parameter | Name:
C02581 | Holding brake: Speed thresholds
Speed setpoint threshold and hysteresis for automatic holding brake control
Setting range
(min. value | unit | max. value)
-199.99
Subcodes
C02581/1
C02581/2
C02581/3
C02581/4
C02581/5
Read access
C02582
Parameter | Name:
C02582 | Holding brake: Setting
Activation of functional holding brake control options
Setting range
(min. hex value | max. hex value)
0x00
Value is bit-coded: (
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 Brake control off
11 Manually controlled
12 Autom. controlled
13 Semi-automat. controlled
Write access
CINH
PLC STOP
%
Lenze setting
5.00 %
1.00 %
1.00 %
0.00 %
0.00 %
Write access
CINH
PLC STOP
= bit set)
L
8400 HighLine C | Reference manual
Info
No holding brake is used. Internal control is switched off.
The holding brake is released and closed via a control bit
in the MCK control word.
The holding brake is automatically released and closed
via speed setpoint comparisons.
From version 06.00.00
The holding brake is released and closed via a control bit
in the MCK control word.
• In contrast to the manual operation (mode 11)
– the feedforward control is active in this mode,
preventing a sagging e.g. in case of a hoist.
– the brake in this mode also closes when the
controller is inhibited in order to prevent the axis in
a hoist from falling.
No transfer
COM
MOT
Scaling factor: 1
199.99
Info
Holding brake: Switching threshold
• Switching threshold of the speed setpoint from which
on the holding brake is released/applied
automatically.
Holding brake: Hyst.release
• Hysteresis for holding brake release.
• Release threshold = switching threshold + release
hysteresis
Holding brake: Hyst. close
• Hysteresis for holding brake application.
• Application threshold = switching threshold -
application hysteresis
Holding brake: FF control starting value 1
From version 06.00.00
Holding brake: FF control starting value 2
From version 06.00.00
No transfer
COM
MOT
Scaling factor: 100
Lenze setting
0xFF 0x40 (decimal: 64)
Info
Parameter reference
Parameter list | C02580
Data type: UNSIGNED_8
Index: 21995
= 55EB
d
h
Holding brake control
Data type: INTEGER_16
Index: 21994
= 55EA
d
h
Holding brake control
Data type: UNSIGNED_8
Index: 21993
= 55E9
d
h
Holding brake control
963

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents