Lenze L-force HighLine C 8400 Series Reference Manual page 75

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

The Encoder/Feedback system parameterisation dialog will be shown:
3. In the
4. Set the number of position encoder increments in the
increments at FreqIn12 input field (C00420/1).
5. In the
track)".
– This selection ensures that the digital DI1 and DI2 input terminals are configured as
frequency inputs.
6. Adapt the proportional gain, Kp position controller (C00115/1), if necessary. This
parameter can be found on the second page of the dialog and can be reached via the
>>> button.
7. Click the Close button to close the parameterisation dialog again.
Related topics:
Digital input terminals
Using DI1(6) and DI2(7) as frequency inputs
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Commissioning of the "Table positioning" technology application
Position encoder selection list field (C00490), select "Encoder signal FreqIn12".
Fct. DI 1/2 100kHz list field (C00115/1), select "DI1(6)&DI2(7)=FreqIn (2-
( 310)
L
8400 HighLine C | Reference manual
Number of encoder
( 314)
Commissioning