8400 HighLine C | Reference manual
Parameter reference
Parameter list | C01297
C01297
Parameter | Name:
C01297 | L_MckStateInterface_1: Alternative function
Selection of the alternative function for bit 16 (PosExecute) in the MCK control word
Setting range
(min. hex value | max. hex value)
0x00
Value is bit-coded: (
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Read access
954
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
= bit set)
PosStop with PosExecute = FALSE
HomingStartStop with PosExecute
SetProfilPosition with PosExecute
SetProfilPosition at position change
Profile start at position change
Write access
CINH
PLC STOP
L
Alternative functions for "PosExecute" control bit
Lenze setting
0xFF 0x03 (decimal: 3)
Info
"1" ≡ Stop positioning with PosExecute
• PosExecute="0" stops a running positioning process
by ramp-down to standstill.
"1" ≡ Start/stop homing with PosExecute
• PosExecute="1" starts homing, PosExecute="0" stops
homing in the "Homing" mode.
"1" ≡ Teach set position with PosExecute
• PosExecute="0->1" accepts the setpoint position at
the MCK in the profile with the specified profile
number.
"1" ≡ Automatic acceptance of set position
• The set position pending at the MCKInterface is
automatically transferred to the profile with the
preset profile number if a data change at the
corresponding input for the setpoijnt is detected.
From version 11.00.00
"1" ≡ Automatic profile start at position change
• An automatic "PosExecute" takes place if the
incremental position selection changes and this
change is higher than set in the hysteresis for position
change (C01245/3).
No transfer
COM
MOT
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_8
Index: 23278
= 5AEE