4.2.6

SwitchedOn

LED DRIVE READY
The drive is in this device status if the DC bus voltage is applied and the controller is still
inhibited by the user (controller inhibit).
 The bus systems are running and the terminals and encoders are evaluated.
 The monitoring modes are active.
 The application is basically executable.
If the controller inhibit is deactivated, the devices changes to the "OperationEnabled"
status and the motor follows the setpoint defined by the active application.
Tip!
C00158
controller inhibit.
Depending on certain conditions, a status change takes place based on the "SwitchedOn"
device status:
Change condition
Control bit "EnableOperation" of all control channels = "1"
AND terminal RFR = HIGH level (controller enable)
Control bit "SwitchOn" of a control channel = "0".
Motor parameter identification requested.
Undervoltage in the DC bus.
Error with error response "Trouble" occurs.
Error with error response "TroubleQSP" occurs.
Related topics:
wCANControl/wMCIControl control words
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
LED DRIVE ERROR
Display in
OFF
SwitchedON
provides a bit coded representation of all active sources/triggers of a
L
8400 HighLine C | Reference manual
Device control (DCTRL)
Device state machine and device statuses
C00137
Display in status word 1 (C00150)
Bit 11
Bit 10
0
1
Changeover to the device status
OperationEnabled
ReadyToSwitchOn
MotorIdent
Trouble/Fault
(depending on C00600/1)
Trouble
TroubleQSP
( 128)
Bit 9
Bit 8
0
0