C00650
Parameter | Name:
C00650 | L_Arithmetik 3-5: Function
Selection of the internal arithmetics
Selection list
Subcodes
C00650/1
C00650/2
C00650/3
Read access
C00660
Parameter | Name:
C00660 | L_FixSet_a_1: Analog values
From version 04.00.00
FB L_FixSet_a_1: Setting of the fixed values
Setting range
(min. value | unit | max. value)
-199.99
Subcodes
C00660/1
C00660/...
C00660/16
Read access
C00661
Parameter | Name:
C00661 | L_FixSet_w_1: Fixed values
From version 04.00.00
FB L_FixSet_w_1: Setting of the fixed values
Setting range
(min. value | unit | max. value)
0
Subcodes
C00661/1
C00661/...
C00661/16
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 nOut_a = nIn1_a
1 nOut_a = nIn1_a + nIn2_a
2 nOut_a = nIn1_a - nIn2_a
3 nOut_a = (nIn1_a * nIn2_a) / 100%
4 nOut_a = (nIn1_a * 1%) / |nIn2_a|
5 nOut_a = (nIn1_a * 100%) / (100% -
nIn2_a)
Lenze setting
0: nOut_a = nIn1_a
0: nOut_a = nIn1_a
0: nOut_a = nIn1_a
Write access
CINH
PLC STOP
%
Lenze setting
0.00 %
Write access
CINH
PLC STOP
Lenze setting
0
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Info
L_Arithmetik_3: Function
L_Arithmetik_4: Function
L_Arithmetik_5: Function
No transfer
COM
MOT
Scaling factor: 1
199.99
Info
Fixed value 0 ... 15
No transfer
COM
MOT
Scaling factor: 100
65535
Info
Fixed value 0 ... 15
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00650
Data type: UNSIGNED_8
Index: 23925
= 5D75
d
h
Data type: INTEGER_16
Index: 23915
= 5D6B
d
h
Data type: UNSIGNED_16
Index: 23914
= 5D6A
d
h
827