8400 HighLine C | Reference manual
I/O terminals
User-defined terminal assignment
Possibility 2: Change terminal assignment by means of the signal flow shown
Procedure:
1. Go to the Application parameters tab.
2. Go to the Application Parameters tab and click on the Signal flow button in order to
change to the dialog level Overview  Signal flow.
3. On the dialog level Overview  Signal flow, click on the Digital control signals button in
order to open the Digital control signals dialog box:
4. In the bJogSpeed2 list field, set the selection "0: Not interconnected".
5. In the bJogRamp1 list field, set the selection "16001: DigIn_bIn2".
6. Click on the Back button in order to close the dialog box again.