Lenze L-force HighLine C 8400 Series Reference Manual page 966

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Parameter reference
Parameter list | C02607
C02607
Parameter | Name:
C02607 | Holding brake: Status
Switching status of the holding brake control
Display area
(min. hex value | max. hex value)
0x0000
Value is bit-coded:
Bit 0 Brake applied
Bit 1 Brake released
Bit 2 Feedforward control active
Bit 3 Closing active
Bit 4 Forced release active
Bit 5 Release active
Bit 6 Setpoint synchronisation active
Bit 7 Signalling contact error
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Read access
C02610
Parameter | Name:
C02610 | MCK: Accel./decel. times
Ramp times for speed setpoint synchronisation
Setting range
(min. value | unit | max. value)
0.000
Subcodes
C02610/1
C02610/2
C02610/3
Read access
966
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Write access
CINH
PLC STOP
s
Lenze setting
2.000 s
2.000 s
2.000 s
Write access
CINH
PLC STOP
L
0xFFFF
Info
Holding brake is completely applied
Holding brake is completely released
Feedforward control for holding of the load via the motor
is active before the holding brake releases.
The brake closing time (C02589/1) expires
In case of automatic operation of the holding brake
control, the brake is directly released via the MCK input
bMBrakeRelease = TRUE
The brake release time (C02589/2) expires
A speed setpoint at the MCK is approached along a
defined ramp after brake release
The status monitoring has tripped.
No transfer
COM
MOT
999.999
Info
Holding brake: ramp time synchr.
• Ramp time for the synchronisation process to
setpoint speed after the brake opening time has
elapsed
Revised behaviour from version 11.00.00:
• The setting made here is only effective if bit 6
"SyncRampe L_NSet_1" in
• In the Lenze setting of
time of the effective acceleration of the ramp
function generator (L_NSet_1) is used.
Holding brake control
MCK: Ramp time synchr. setpoint
• Time for synchronisation ramps between setpoint
jumps occurring through the exceedance of
minimum and maximum speed setpoint limit ranges.
MCK: SM stopping ramp
No transfer
COM
MOT
Scaling factor: 1000
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_16
Index: 21968
= 55D0
d
h
Holding brake control
Data type: UNSIGNED_32
Index: 21965
= 55CD
d
h
C02582
is set to "0".
C02582
(Bit 6 = "1"), the ramp