8.4.3

Limit position monitoring

8.4.3.1

Software limit positions

The parameterisable limit positions are used by the software to limit the traversing range.
 The positive software limit position is set in
position is set in C01229/2.
Stop!
The software limit positions are only evaluated and monitoring if the drive
knows the home position and the software limit positions for the respective
operating mode have been activated.
• For the "manual jogging" operating mode, travel range monitoring is
switched off by means of parameterisable software limit positions in the
Lenze setting of C01230.
• In the "Homing" and "Positioning" operating modes, the travel range
monitoring is generally switched-on.
Parameter
C01218
- Bit 3
C01219
- Bit 3
C01230
- Bit 3
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Info
SW limit positions for position follower on/off
SW limit positions for speed follower on/off
SW limit position for manual jogging on/off
L
8400 HighLine C | Reference manual
Basic drive functions (MCK)
C01229/1
and the negative software limit
Basic settings
Lenze setting
On
On
Off