Lenze L-force HighLine C 8400 Series Reference Manual page 397

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

Identifier
bGPLogicIn1
bGPLogicIn2
bGPLogicIn3
nGPCompareIn1_a
nGPCompareIn2_a
bGPDFlipFlop_InD
bGPDFlipFlop_InClk
bGPDFlipFlop_InClr
bGPCounter1ClkUp
bGPCounter1ClkDown
bGPCounter1Load
wGPCounter1LdVal
wGPCounter1CmpVal
Free inputs
The following inputs can freely be interconnected on the application level.
The signals can be transferred from the I/O level to the application level via these inputs.
bFreeIn1 ... bFreeIn8
wFreeIn1 ... wFreeIn4
dnFreeIn1_p ... dnFreeIn2_p
Outputs
Identifier
wDriveControlStatus
wStateDetermFailNoLow
wStateDetermFailNoHigh
bDriveFail
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Information/possible settings
Data type
Binary
logic: Input signals
• The logic operation is selected in C00820.
• The result is output at output bGPLogicOut.
BOOL
Analog
comparison: Input signals
• The comparison operation is selected in C00680.
• Hysteresis and window size can be set in
INT
• If the comparison statement is true, the output bGPCompareOut will be set to
TRUE.
D-FlipFlop: Input signals
• Data, clock and reset input
BOOL
Numerator: Clock input
• With each edge, the module counts up by "1".
BOOL
• Only FALSE-TRUE edges are evaluated.
Note: The static state "1" is not permissible at this input.
Numerator: Clock input
• With each edge, the module counts down by "1".
BOOL
• Only FALSE-TRUE edges are evaluated.
Note: The static state "1" is not permissible at this input.
Numerator: Loading input
• The input has the highest priority.
BOOL
TRUE Accept the starting value wGPCounter1LdVal.
Numerator: Starting value
• Assigned value is internally interpreted as "INT" data type (-32767 ... +32767), i.e.
WORD
the most significant bit determines the sign.
Numerator: Comparison value
• Assigned value is internally interpreted as "INT" data type (-32767 ... +32767), i.e.
WORD
the most significant bit determines the sign.
Free inputs for digital signals
BOOL
Free inputs for 16-bit signals
WORD
Free inputs for 32-bit signals
DINT
Value/meaning
Data type
Status word of the controller (based on DSP-402)
• The status word contains information on the currents status of the drive
WORD
controller.
• See the
"wDeviceStatusWord status
control for a detailed description of the bit assignment.
Display of the status determining error (LOW word)
WORD
Display of the status determining error (HIGH word)
WORD
TRUE Drive controller in error status.
• "Fault" device status is active.
BOOL
L
8400 HighLine C | Reference manual
Technology applications
C00680
and C00682.
word" subchapter of the chapter on device
TA "Table positioning"
397

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents