Lenze L-force HighLine C 8400 Series Reference Manual page 573

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

9.6
Monitoring
The controller is provided with various monitoring functions which protect the drive
against impermissible operating conditions.
 If a monitoring function responds,
– an entry will be made into the
– the response (TroubleQSP, Warning, Fault, etc.) set for this monitoring function will
be triggered,
– the status of the internal device control changes according to the selected response,
controller inhibit is set, and the "DRIVE ERROR" LED on the front of the controller goes
on:
Response
None
Fault
Trouble
TroubleQSP
WarningLocked
Warning
Information
System error
Related topics:
LED status displays of the device status
Device state machine and device statuses
Device overload monitoring (Ixt)
Motor load monitoring (I2xt)
Motor temperature monitoring (PTC)
Brake resistor monitoring (I2xt)
Motor phase failure monitoring
Mains phase failure monitoring
Maximum current monitoring
Maximum torque monitoring
Encoder open-circuit monitoring
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Logbook
Entry in the
Display in
logbook
C00168
( 289)
( 290)
( 293)
( 295)
( 298)
( 298)
( 299)
( 300)
L
8400 HighLine C | Reference manual
Diagnostics & error management
of the controller,
Pulse inhibit
Controller
inhibit
(after 0.5 s)
( 561)
( 111)
( 292)
Monitoring
Acknowledge
LED
ment
"DRIVE ERROR"
required
OFF
OFF
Mains
switching
is required!
573

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents