8400 HighLine C | Reference manual
Basic drive functions (MCK)
Homing
Mode 11: <_Ln_>_TP
 Touch probe
 Negative travel range limit switch
Mode 11
Lp
Ln
Functional sequence:
1. Movement in negative direction with start profile data set.
2. Reversing when the edge of the negative travel range limit switch is positive and, at the
same time, activation of search profile data set for continued reference searching.
3. Negative edge of the travel range limit switch enables home position detection.
4. Following edge of the touch probe sensor sets home position.
502
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
1
0
1
<
Ln
>
Start speed
Inactive
Inactive
Active
Inactive
Inactive
Inactive
L
TP
Offset path
Sequence profile (optional)
Search speed
Active
Active
Inactive
Inactive
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Profile speed
Active
Active