Acceptance with SH + PRG with controller inhibit
The axis module accepts the new parameter when it has been
inhibited prior to pressing SH + PRG. Inhibit the controller e.g. by
pressing STP. First press SH and then in addition PRG. The
display shows --ok-- for 0.5 seconds. The axis module works with
the new parameter when the controller is released again. If you
have to set a parameter of a code in this way, the symbol
appears in the code table.
2.2.
• When commissioning for the first time, the parameter set 1 is
factory-set. After the acceptance, new parameters are saved in
the RAM, i.e. they are saved until the controller is disconnected
from the mains.
If you do not want to lose your setting when connecting the
controller to the mains, save them permanently:
1. Select code C003.
2. Select parameter set 1 by entering -1- .
3. Press SH first, and then additionally PRG. --ok-- will be
4. Now you can disconnect the servo controller from the mains.
• Password
The input of a password prevents unauthorized changes of
parameters or code levels.
2.3.
If you only need one parameter set, you can permanently save
your changes under parameter set 1. After every mains connection,
parameter set 1 is loaded automatically.
42

Save parameters

displayed.
Your settings are permanently saved under "parameter set
1".
Load parameter