Rfi Filter; External Fuses; System Cables; System Cables For Control Terminal Block X5 - Lenze 9215 Operating Instructions Manual

9200 series servo controller
Table of Contents

Advertisement

6.3.
For radio interference suppression according to EN 55011, limit
value class A or B.
Assigned RFI filters for mains voltage of 400 V
Supply module type
Mains current RFI filter
Order no. mains filter
Filter for mains voltages of up to 460 V: please contact
manufacturer
6.4.
Semiconductor protection
External fast acting fuses in the mains input protect the input
rectifier in the supply module.
Recommended semiconductor protection fuses (at mains side):
Supply module
Mains input with
rectifier protection
Order no.
Input cables must be protected with standard fuses adapted to the
cross-sectional area of the cables.
6.5.
Note
For best interference immunity results, cut the cables to the required length.

6.5.1. System cables for control terminal block X5

Design for
Order no.
34

RFI filter

9212
8 A
EZF3_008A001 EZF3_025A001 EZF3_050A004

External fuses

9212
FF
20A / 700V
14 x 51
EFSFF0200ARH

System cables

left X5 terminals
EW00340899
9215
9217
25 A
50 A
9215
9217
FF
FF
63A / 700V
100A / 700V
22 x 58
22 x 58
EFSFF0630ARI
EFSFF1000ARI
right X5 terminals
EW00340898
Fehler! Es
ist nicht
möglich,
durch die
B
b it


Hide quick links: