Generate Parameter Set - Lenze 9300 Operating Instructions Manual

Servo positioning controller
Hide thumbs Also See for 9300:
Table of Contents

Advertisement

Show/Hide Bookmarks
Commissioning
5.6

Generate parameter set

Warning!
Do not change any controller settings that are not mentioned in this chapter. For more complex
positioning tasks consult the Manual.
The instructions for the generation of a parameter set in this Chapter are based on the factory
setting.
Proceed systematically when generating a parameter set:
1. Adapt controller to mains conditions.
2. Adapt controller to motor.
3. Enter machine parameters.
4. Enter parameters for manual positioning. (Then carry out a function test.)
5. Enter parameters for positioning profile.
Tip!
Make a positioning profile of your positioning task and, using this drawing, determine as much
positioning data as possible.
5.6.1
Adapt controller to the mains
1
2
3
4
Fig. 5-3
"Basic settings" dialog box
Field
1
5-6
^
(
5-13)
Command
Click on field
BA9300POS EN 2.3
Function
Select values for the actual mains and operating conditions.

Hide quick links:

Advertisement

Table of Contents
loading