Analog Inputs Via Terminal X6/1, X6/2 And X6/3, X6/4 (Ain) - Lenze 9300 Series System Manual

Servo position controllers
Hide thumbs Also See for 9300 Series:
Table of Contents

Advertisement

Function library
Function blocks
3.5.5

Analog inputs via terminal X6/1, X6/2 and X6/3, X6/4 (AIN)

3.5.5
Analog inputs via terminal X6/1, X6/2 and X6/3, X6/4 (AIN)
Purpose
These function blocks are the interface for analog signals as the
l
setpoint input,
l
actual value input and
l
parameter control.
1
2
Fig. 3−47
Analog input via terminal X6/1, X6/2 (AIN1)
Name
AIN1−OFFSET
AIN1−GAIN
AIN1−OUT
Special features of AIN1
l
A dead band element can be integrated into the output signal at AIN1 via code C0034.
Together with the jumper position X2 (controller front) the function 4 ... 20 mA can be
implemented as a master current value.
l
The signal is read cyclically (1 ms).
3
4
Fig. 3−48
Analog input via terminal X6/3, X6/4 (AIN2)
Name
AIN2−OFFSET
AIN2−GAIN
AIN2−OUT
Special feature of AIN2
The signal is read cyclically every 250 ms.
l
3−102
C0034
+
+
AIN1-OFFSET
C0402
C0404/1
AIN1-GAIN
C0403
C0404/2
Signal
Type
DIS
DIS format
a
C0404/1
dec [%]
a
C0404/2
dec [%]
a
C0400
AIN2
AIN2-OUT
+
+
AIN2-OFFSET
C0405
C0407
C0409/1
AIN2-GAIN
C0408
C0409/2
Signal
Type
DIS
DIS format
a
C0409/1
dec [%]
a
C0409/2
dec [%]
a
C0405
EDSVS9332P−EXT DE 2.0
AIN1
AIN1-OUT
C0400
Source
CFG
List
Lenze
C0402
1
19502
C0403
1
19504
Source
CFG
List
Lenze
C0407
1
19503
C0408
1
19505
Note
Note
l

Hide quick links:

Advertisement

Table of Contents
loading