Feedback Systems - Lenze 9300 Operating Instructions Manual

Servo positioning controller
Hide thumbs Also See for 9300:
Table of Contents

Advertisement

Show/Hide Bookmarks
Installation
4.2.10

Feedback systems

Different feedback systems can be connected to the controller:
Resolver feedback (factory setting)
Encoder feedback
– Incremental encoder TTL
– Sin/cos encoder
– Sin/cos encoder with serial communication (single turn)
– Sin/cos encoder with serial communication (multi turn)
Resolver signal or encoder signal can be output for slaves at the digital frequency output X10.
Connection as shown in the figures:
– Use twisted pair cables and screened pair cables.
– Connect the screen at both ends.
– Use indicated cable cross-sections.
The feedback system is activated under C0025.
Sensorless control SSC
The sensorless controller (SSC) should not be used for new drive solutions (C0025 = 1).
Instead use a vector control EVF 9300 or contact Lenze.
4-30