ADTRAN AOS Version R10.1.0 Command Reference Manual page 2178

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
frame-relay lmi-n392dte <value>
Use the frame-relay lmi-n392dte command to set the N392 error threshold for the data terminal
equipment (DTE) endpoint. Typical applications should leave the default value for this setting. Use the no
form of this command to return to the default value.
Syntax Description
<value>
Default Values
By default, the error threshold for the DTE endpoint is set to three errors.
Command History
Release 1.1
Functional Notes
If the error threshold is met, the signaling state status is changed to down, indicating a service-affecting
condition. This condition is cleared once N393 consecutive error-free events are received. N392 defines
the number of errors required in a given event window, while N393 defines the number of polling events in
each window.
For example:
If N392 = 3 and N393 = 4, then if three errors occur within any four events, the interface is determined
inactive.
Usage Examples
The following example sets the N392 threshold for five errors:
(config)#interface frame-relay 1
(config-fr 1)#frame-relay lmi-n392dte 5
60000CRG0-35E
Sets the error threshold value. Valid range is 1 to 10 errors.
Command was introduced.
Copyright © 2012 ADTRAN, Inc.
Frame Relay Interface Command Set
2178