Command Reference Guide
frame-relay lmi-n391dte <value>
Use the frame-relay lmi-n391dte command to set the N391 full status polling counter for the data
terminal equipment (DTE) endpoint. Typical applications should leave the default value for this timer. Use
the no form of this command to return to the default value.
Syntax Description
<value>
Default Values
By default, the polling counter for the DTE endpoint is set to six polls.
Command History
Release 1.1
Functional Notes
The N391 counter determines how many link integrity polls occur in between full status polls. The number
of link integrity polls between full status polls is n - 1, where n represents the full status poll. n can be set to
any number between 1 and 255, but the default is used for most applications.
Usage Examples
The following example sets the N391 counter for three polls:
(config)#interface frame-relay 1
(config-fr 1)#frame-relay lmi-n391dte 3
60000CRG0-35E
Sets the poll counter value. Valid range is 1 to 255.
Command was introduced.