Speed Limit Values - Lenze E84AVSC Operating Instructions Manual

Controller/inverter drive
Table of Contents

Advertisement

8400 StateLine C | Operating instructions
Adapting the application individually
Activating additional functions in the signal flow
8.2.1

Speed limit values

C00635
L_NSet_1: nMaxLimit
Maximum speed setpoint for speed setpoint limitation
Setting range
(min. value | unit | max. value)
-199.99
C00636
L_NSet_1: nMinLimit
Minimum speed setpoint for speed setpoint limitation
Setting range
(min. value | unit | max. value)
-199.99
C02611/x
MCK: Limitations
Speed setpoint limits for the determination of limited validity ranges
Note:
Traversing with setpoints through resulting blocking zones is executed with the ramp set in C02610/2:
v
C02611/1
C02611/2
C02610/2
C02611/3
C02611/4
 setpoint range
Setting range
(min. value | unit | max. value)
0.00
Subcodes
C02611/1
C02611/2
C02611/3
C02611/4
60
%
%
nSpeedSetValue_a
0
1
0
 synchronisation range
%
Lenze setting
199.99 %
0.00 %
0.00 %
199.99 %
L
Lenze setting
199.99 199.99 %
Lenze setting
199.99 -199.99 %
nSpeedSetValue_a_
Sync
199.99
Info
MCK: Pos. max. speed
• Upper limit of the speed setpoint limitation in
positive direction of rotation.
MCK: Pos. min. speed
• Lower limit of the speed setpoint limitation in
positive direction of rotation.
MCK: Neg. min. speed
• Lower limit of the speed setpoint limitation in
negative direction of rotation.
MCK: Neg. max. speed
• Upper limit of the speed setpoint limitation in
negative direction of rotation.
from Firmware V06.00 - DMS 1.1 EN - 11/2011
t
Sync

Advertisement

Table of Contents
loading