frequency

frequency frequencyValue
Syntax
no frequency
Command introduced before JUNOSe Release 7.1.0.
Release Information
In RTR Configuration mode, sets the time interval between RTR operations. In SNMP
Description
Event Manager Configuration mode, sets the frequency (in seconds) at which you
want MIB sampling to occur. The no version restores the default value.
Options
RTR Configuration, SNMP Event Manager Configuration
Mode
frequencyValue Number of seconds between RTR operations or MIB sampling
operations, depending on the configuration mode; with RTR operations, for both
types (echo and pathEcho), the default value is 60 seconds; with MIB sampling,
the default value is 600 seconds.
Chapter 7: F Commands
659
frequency