Frequency Of Fdl Path Messages; Higher-Level Protocols; Platform Considerations; Configuring Channelized T3 Interfaces - Juniper JUNOSE 11.2.X PHYSICAL LAYER Configuration Manual

For e series broadband services routers - physical layer configuration
Table of Contents

Advertisement

Higher-Level Protocols

Platform Considerations

Copyright © 2010, Juniper Networks, Inc.
Table 3: MDL and FDL Message Strings and Message Types (continued)
Message
String
Description
port
Equipment port number
unit
Unit identification code
As long as another message of any type containing the same string is received within 10
seconds, the line module retains the local copy of the message string and resets the
10-second timer for that string.
For example, if a line module receives an MDL or FDL test signal message containing an
eic string, and then receives an idle signal message within 10 seconds that also contains
an eic string, it retains the local copy of the most recent eic string received and resets the
10-second timer for that message. However, if 10 seconds pass without the line module
receiving a path identification, test signal, or idle signal message containing an eic string,
the line module erases the local copy of the eic message string.
For message strings that are unique to a particular message type, the line module must
receive another message of the same type containing this string in order to retain the
local copy of the string and reset the timer. For example, if the line module receives a
test signal message containing a generator string and does not receive another test signal
message within 10 seconds, it will erase the local copy of the generator string.

Frequency of FDL Path Messages

E Series Routers transmit FDL path identifier messages every second. This behavior
complies with the ANSI T1.403 specification (see "References" on page 9 for more
information) and is consistent with the MDL implementation for E Series Routers.
See ERX Module Guide, Appendix A, Module Protocol Support for information about the
higher-level protocols that channelized T3 interfaces support.
You can configure channelized T3 interfaces on the following Juniper Networks E Series
Broadband Services Routers:
ERX1440 router
ERX1410 router
ERX710 router
ERX705 router
ERX310 router
Chapter 1: Configuring Channelized T3 Interfaces
Path
Idle Signal
Message
Message
Test Signal
Message
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junose 11.2.x

Table of Contents