JUNOSe 11.1.x Command Reference Guide A to M
clock source
clock source { line | internal { module | chassis } }
Syntax
no clock source
Command introduced before JUNOSe Release 7.1.0.
Release Information
Determines how an interfaces obtains clocking signals. The no version restores the
Description
default value, line.
Options
Controller Configuration, Interface Configuration (POS only)
Mode
438
clock source
line Interface clocks data from a clock recovered from the line's receive data
stream; the default.
internal Internal clock source transmits data from its internal clock. You must
specify one of the following for internal clocking:
module Internal clock is from the line module itself
chassis Internal clock is from the configured system clock