check-disk

check-disk [ repair ] [ disk0 | disk1 ]
Syntax
Command introduced before JUNOSe Release 7.1.0.
Release Information
disk0 and disk1 keywords added in JUNOSe Release 7.2.0.
Privileged Exec mode added in JUNOSe Release 8.0.0.
Finds and repairs structural inconsistencies and damage in the DOS file system in
Description
unmounted flash cards on the primary SRP module. There is no no version.
Options
Boot, Privileged Exec
Mode
disk0 Specifies flash card in slot 0 of the SRP module; default value is disk0;
available only in Boot mode, because disk0 cannot be in an unmounted state in
a router outside of Boot mode
disk1 Specifies flash card in slot 1 of the SRP module; supported only on the
E120 router and the E320 router