11.4
Preset Speeds & Speed Pot (2-Wire Start/Stop Control)
1
2
5
Maintained
RUN/STOP
Contact
NOTE:
For preset speed control, all or some of the TB-13 termnals must be
programmed as preset speed selects . If only two or three preset speeds are
requred, only two of the TB-13 termnals must be used . Refer to the table n
the descrpton of Parameters 31-37 n Secton 15 .
Program the PRESET SPEEDS (Parameters 31-37) to the desred values .
If speed pot control s desred when none of the preset speeds are selected (all
preset speed selects are open to TB-11), set STANDARD SPEED SOURCE
(Parameter 05) to 0-10 VDC (03) .
11
6
13A
SPEED
POT
Speed Potentometer
13B
13E
25
21
FORM A RELAY
17
16
SM01M