13.6.2

SCI Initialization (Clock Synchronous Mode)

Before transmitting and receiving data, you should first clear the TE and RE bits in SCR to 0, then
initialize the SCI as described in a sample flowchart in figure 13.15. When the operating mode,
transfer format, etc., is changed, the TE and RE bits must be cleared to 0 before making the
change using the following procedure. When the TE bit is cleared to 0, the TDRE flag in SSR is
set to 1. However, clearing the RE bit to 0 does not initialize the RDRF, PER, FER, and ORER
flags in SSR, or RDR.
Start initialization
Clear TE and RE bits in SCR to 0
Set CKE1 and CKE0 bits in SCR
(TE and RE bits are 0)
Set data transfer format in
SMR and SCMR
Set value in BRR
1-bit interval elapsed?
Set TE and RE bits in SCR to 1, and
set RIE, TIE, TEIE, and MPIE bits
<Transfer start>
Note: In simultaneous transmit and receive operations, the TE and RE bits should both be cleared
to 0 or set to 1 simultaneously.
[1]
[2]
[3]
Wait
No
Yes
[4]
Figure 13.15 Sample SCI Initialization Flowchart
Section 13 Serial Communication Interface (SCI)
[1] Set the clock selection in SCR. Be sure
to clear bits RIE, TIE, TEIE, and MPIE,
TE and RE to 0.
[2] Set the data transfer format in SMR and
SCMR.
[3] Write a value corresponding to the bit
rate to BRR. This step is not necessary
if an external clock is used.
[4] Wait at least one bit interval, then set
the TE bit or RE bit in SCR to 1.
Also set the RIE, TIE TEIE, and MPIE
bits.
Setting the TE and RE bits enables the
TxD and RxD pins to be used.
Rev. 1.00 Mar. 12, 2008 Page 467 of 1178