Table 22.3 shows a specific example of setting.
Table 22.3 Example of Setting
Endpoint
Number
Conf.
Int.
0
1
1
0
2
1
0
3
1
0
1
1
1
1
N
EPIR[N]0
0
00
1
14
2
24
3
34
4
00
5
00
6
00
7
00
8
00
9
00
Configuration
Interface
1
Transfer
Alt.
Method
Control
0
Bulk
0
Bulk
0
Interrupt
0
1
EPIR[N]1
00
20
28
38
00
00
00
00
00
00
Alternate
Setting
0
0
Section 22 USB Function Module (USB)
Transfer
Direction
In/Out
Out
In
In
EPIR[N]2
EPIR[N]3
10
00
80
00
80
00
10
00
00
00
00
00
00
00
00
00
00
00
00
00
Endpoint
Number
0
1
2
3
Rev. 1.00 Mar. 12, 2008 Page 859 of 1178
Maximum
Endpoint
Packet Size
FIFO Number
8 bytes
0
64 bytes
1
64 bytes
2
8 bytes
3
EPIR[N]4
00
01
02
03
00
00
00
00
00
00
Endpoint
FIFO Number
Attribute
0
Control
1
BulkOut
2
BulkIn
3
InterruptIn
REJ09B0403-0100