Section 13 Serial Communication Interface (SCI)
13.9.6

Restrictions on Using DTC

When the external clock source is used as a synchronization clock, update TDR by the DTC and
wait for at least five φ clock cycles before allowing the transmit clock to be input. If the transmit
clock is input within four clock cycles after TDR modification, the SCI may malfunction (figure
13.33).
When using the DTC to read RDR, be sure to set the receive end interrupt source (RXI) as a DTC
activation source.
SCK
TDRE
Serial data
Note: When external clock is supplied, t must be more than four clock cycles.
Figure 13.33 Sample Transmission using DTC in Clock Synchronous Mode
Rev. 1.00 Mar. 12, 2008 Page 490 of 1178
REJ09B0403-0100
t
LSB
D0
D1
D2
D3
D4
D5
D6
D7