Download Print this page

Renesas H8S Family Hardware Manual page 524

Advertisement

Section 13 Serial Communication Interface (SCI)
In normal transmission/reception
Ds
When a parity error is generated
Ds
[Legend]
Ds:
Start bit
D0 to D7: Data bits
Dp:
Parity bit
DE:
Error signal
Figure 13.22 Data Formats in Normal Smart Card Interface Mode
For communication with the IC cards of the direct convention and inverse convention types,
follow the procedure below.
(Z)
Figure 13.23 Direct Convention (SDIR = SINV = O/E = 0)
For the direct convention type, logic levels 1 and 0 correspond to states Z and A, respectively, and
data is transferred with LSB-first as the start character, as shown in figure 13.23. Therefore, data
in the start character in the figure is H'3B. When using the direct convention type, write 0 to both
the SDIR and SINV bits in SCMR. Write 0 to the O/E bit in SMR in order to use even parity,
which is prescribed by the smart card standard.
(Z)
Figure 13.24 Inverse Convention (SDIR = SINV = O/E = 1)
Rev. 1.00 Mar. 12, 2008 Page 476 of 1178
REJ09B0403-0100
D0
D1
D2
D3
Output from the transmitting station
D0
D1
D2
D3
Output from the transmitting station
A
Z
Z
A
Z
Ds
D0
D1
D2
D3
A
Z
Z
A
A
Ds
D7
D6
D5
D4
D4
D5
D6
D7
D4
D5
D6
D7
Z
Z
A
A
Z
D4
D5
D6
D7
Dp
A
A
A
A
Z
D3
D2
D1
D0
Dp
Dp
Dp
DE
Output from
the receiving station
(Z) state
(Z) state

Advertisement

loading

This manual is also suitable for:

R4f2472R4f2462H8s/2462H8s/2400 seriesH8s/2472