Download Print this page

Renesas H8S Family Hardware Manual page 518

Advertisement

Section 13 Serial Communication Interface (SCI)
Initialization
Start transmission
Read TDRE flag in SSR
TDRE = 1
Write transmit data to TDR and
clear TDRE flag in SSR to 0
All data transmitted?
Read TEND flag in SSR
TEND = 1
Clear TE bit in SCR to 0
<End>
Rev. 1.00 Mar. 12, 2008 Page 470 of 1178
REJ09B0403-0100
No
Yes
No
Yes
No
Yes
Figure 13.17 Sample Serial Transmission Flowchart
[1] SCI initialization:
[1]
The TxD pin is automatically
designated as the transmit data output
pin.
[2] SCI status check and transmit data
[2]
write:
Read SSR and check that the TDRE
flag is set to 1, then write transmit data
to TDR and clear the TDRE flag to 0.
[3] Serial transmission continuation
procedure:
To continue serial transmission, be
sure to read 1 from the TDRE flag to
confirm that writing is possible, then
write data to TDR, and then clear the
TDRE flag to 0.
However, the TDRE flag is checked
[3]
and cleared automatically when the
DTC is initiated by a transmit data
empty interrupt (TXI) request and
writes data to TDR.

Advertisement

loading

This manual is also suitable for:

R4f2472R4f2462H8s/2462H8s/2400 seriesH8s/2472