register. The day interrupt occurs whenever the day, hour, minute, and
second fields first match those of the RTC status register.
31 30
DAY (31-17)
Alarm Day 0–32767
15
14
HOUR (16-12)
Alarm Hour 0–23
MINUTE (11-6)
Alarm Minute 0–59
Figure A-114. RTC Alarm Register (RW)
Initialization Register (RTC_INIT)
This register, shown in
vides the calibration function, powers down the unit, and grounds these
buses.
15
14
13
RTC_READEN
Output Bus
Enable
Figure A-115. RTC_INIT Register
ADSP-214xx SHARC Processor Hardware Reference
www.BDTIC.com/ADI
29 28 27 26 25 24
23 22
13
12
11 10
9
8
7
Figure A-115
12
11 10
9
8
7
6
5
Registers Reference
21 20 19 18 17 16
HOUR (16-12) (Con't)
Alarm Hour 0–23
6
5
4
3
2
1
0
SECOND (5-0)
Alarm Second 0–59
and described in
4
3
2
1
0
CALIB (3–0)
Time Calibration
RTCPDN
Power Down
Table
A-115, pro-
A-215
Need help?
Do you have a question about the SHARC ADSP-214 Series and is the answer not in the manual?