Updating Revolution Counters; Updating Revolution Counters On Irc5 Robots - ABB IRB 1200 Product Manual

Hide thumbs Also See for IRB 1200:
Table of Contents

Advertisement

5.3 Updating revolution counters

5.3.1 Updating revolution counters on IRC5 robots

Introduction
This section describes how to do a rough calibration of each manipulator axis by
updating the revolution counter for each axis, using the FlexPendant.
Step 1 - Manually running the manipulator to the synchronization position
Use this procedure to manually run the manipulator to the synchronization position.
1
2
3
Step 2 - Updating the revolution counter with the FlexPendant
Use this procedure to update the revolution counter with the FlexPendant (IRC5).
1
Product manual - IRB 1200
3HAC046983-001 Revision: S
Action
Select axis-by-axis motion mode.
Jog the manipulator to align the synchron-
ization marks.
When all axes are positioned, update the
revolution counter.
Action
On the ABB menu, tap Calibration.
xx1500000942
© Copyright 2014 - 2021 ABB. All rights reserved.
5.3.1 Updating revolution counters on IRC5 robots
Note
See
Synchronization marks and synchron-
ization position for axes on page
Step 2 - Updating the revolution counter
with the FlexPendant on page
5 Calibration
810.
813.
Continues on next page
813

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1200-5/0.9Irb 1200-7/0.7

Table of Contents