4.5.1 Replacing the base spare parts (base, axis-1 radial sealing, protection sleeve)
Cabling with bottom interface, and cabling routed from below
Use this procedure if the cable connector interface is located at the bottom of the
base and the cabling is routed from below.
1
2
3
4
5
6
Product manual - IRB 1200
3HAC046983-001 Revision: S
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
replacing parts on page
158.
Open the base cover.
Remove the brake release button from the base
cover.
Disconnect the earth cable.
Remove the cable bracket by removing the
screws.
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
Continued
Note
xx1400000405
xx1400000406
Continues on next page