ABB IRB 1200 Product Manual page 417

Hide thumbs Also See for IRB 1200:
Table of Contents

Advertisement

Concluding procedures
1
2
3
Product manual - IRB 1200
3HAC046983-001 Revision: S
Action
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Clean, seal and paint the joints that have
been opened. See
Cut the paint or surface
on the robot before replacing parts on
page
158.
Note
After all repair work, wipe the robot free
from particles with spirit on a lint free cloth.
Recalibrate the robot.
DANGER
Make sure all safety requirements are met
when performing the first test run.
© Copyright 2014 - 2021 ABB. All rights reserved.
4.4.3 Replacing the tubular spare parts
Note
Calibration information is included in sec-
tion
Calibration on page
4 Repair
Continued
805.
417

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1200-5/0.9Irb 1200-7/0.7

Table of Contents