3 Maintenance
3.4.2 Replacing the sealing set on tool flange of Hygienic robots
Continued
2
3
4
5
Continues on next page
146
Action
Remove the screws and washers.
Insert two M4 screws to the pressed out holes
and press out the stainless shaft.
Place the flange tightening tool together with a
3/8" (10 mm) socket spanner on the seal ring unit
and loosen the unit.
Remove the gasket and seal ring unit.
© Copyright 2014 - 2021 ABB. All rights reserved.
Note
xx2100001449
xx2100001450
xx2100001451
Flange tightening tool:
3HAC079686-001
xx2100001452
xx2100001453