4 Repair
4.4.1 Replacing the lower arm
Continued
7
8
9
Continues on next page
340
Action
Refit the lower arm screws and washers,
using locking liquid Loctite 243.
Secure the screws but do not tighten yet.
Remove the guide pins and refit the remain-
ing screws and washers using locking li-
quid Loctite 243.
Tighten all screws.
© Copyright 2014 - 2021 ABB. All rights reserved.
Note
Screws: 3HAB3409-51 (M10x30).
xx1300002564
Note
Only use specified screws, never replace
them with other screws.
xx1300002565
Tightening torque: 45 Nm
Product manual - IRB 1200
3HAC046983-001 Revision: S