4 Repair
4.2.4 Swing sealing plug for Clean Room, food grade lubrication and Hygienic robots
Continued
Required consumables
Consumable
Sealant
Sealant
Removing the swing sealing plug
1
2
Continues on next page
166
Action
Cut the swing sealing plug through with a sharp
object to get access to the screws.
Remove the cable housing cover of the swing by
removing the screws.
© Copyright 2014 - 2021 ABB. All rights reserved.
Art. no.
Note
3HAC026759-001
Sikaflex 521FC
For robots with protection type
Clean Room
For robots with food grade lubric-
ation
3HAC073510-001
Trans Clear
For robots with protection type
Hygienic
Note
xx1600000206