5 Calibration

5.7 Verifying the calibration

5.7 Verifying the calibration
Introduction
Always verify the results after calibrating any robot axis to verify that all calibration
positions are correct.
Verifying the calibration
Use this procedure to verify the calibration result.
1
2
3
864
Action
Run the calibration home position program twice.
Do not change the position of the robot axes after running
the program!
Adjust the synchronization marks when the calibration is
done, if necessary.
Write down the values on a new label and stick it on top
of the calibration label.
The label is located on one side of the base.