Preparations before securing the axis-5 motor
1
2
Product manual - IRB 1200
3HAC046983-001 Revision: S
Action
Put the cables through the plate hole and refit the
plate.
Reconnect the air hoses.
CAUTION
Make sure to connect the air hoses correctly, ac-
cording to the marking on hoses and connectors.
Reconnect the connectors.
R3.Eth
R3.CPCS
Action
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Check that:
all assembly surfaces are clean and without
damages
the motor is clean and undamaged.
© Copyright 2014 - 2021 ABB. All rights reserved.
4.4.3 Replacing the tubular spare parts
Note
Tightening torque: 0.3 Nm.
xx1300002356
xx1300002355
xx1300002353
Note
Continues on next page
4 Repair
Continued