4 Repair
4.4.3 Replacing the tubular spare parts
Continued
8
9
10
Continues on next page
402
Action
Apply a little grease to the screw thread.
Put the gasket in place and then screw the seal
ring unit.
Place the flange tightening tool together with a
3/8" (10 mm) socket spanner on the seal ring unit
and tighten the unit.
© Copyright 2014 - 2021 ABB. All rights reserved.
Note
Grease: Molykote P1900
xx2100001454
xx2100001453
xx2100001455
Flange tightening tool:
3HAC079686-001
Tightening torque: 6 Nm
xx2100001456