Setting The System Parameters For A Suspended Or Tilted Robot - ABB IRB 1200 Product Manual

Hide thumbs Also See for IRB 1200:
Table of Contents

Advertisement

2 Installation and commissioning

2.3.5 Setting the system parameters for a suspended or tilted robot

2.3.5 Setting the system parameters for a suspended or tilted robot
General
The robot is configured for mounting parallel to the floor, without tilting, on delivery.
The method for mounting the robot in a suspended (upside down) or tilted position
is basically the same as for floor mounting, but the system parameters that describe
the mounting angle (how the robot is oriented relative to the gravity) must be
re-defined.
System parameters
Gravity Beta
If the robot is mounted upside down or on a wall (rotated around the y-axis), then
the robot base frame and the system parameter Gravity Beta must be redefined.
Gravity Beta should then be π (+3.141593) if the robot is mounted upside down
(suspended), or ±π/2 (±1.570796) if mounted on a wall.
The Gravity Beta is a positive rotation direction around the y-axis in the base
coordinate system. The value is set in radians.
Gravity Alpha
If the robot is mounted on a wall (rotated around the x-axis), then the robot base
frame and the system parameter Gravity Alpha must be redefined. The value of
Gravity Alpha should then be ±π/2 (±1.570796).
Continues on next page
78
Note
With suspended installation, make sure that the gantry or corresponding structure
is rigid enough to prevent unacceptable vibrations and deflections, so that
optimum performance can be achieved.
Note
The allowed mounting positions are described in the product specification for
the robot. The requirements on the foundation are described in
foundation on page
52.
Note
The mounting angle must be configured correctly in the system parameters so
that the robot system can control the movements in the best possible way. An
incorrect definition of the mounting angle will result in:
Overloading the mechanical structure.
Lower path performance and path accuracy.
Some functions will not work properly, for example Load Identification and
Collision detection.
© Copyright 2014 - 2021 ABB. All rights reserved.
Requirements,
Product manual - IRB 1200
3HAC046983-001 Revision: S

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1200-5/0.9Irb 1200-7/0.7

Table of Contents